PASONDIA CABLES
wires and cables pasondia cables
   
 

PVC INSULTED FLEXIBLE ISI MARKED HOUSE WIRING CABLES CONFORMING TO IS : 694-1990
SINGLE CORE UNSHEATHED CABLES VOLTAGE GRADE 650/1100 VOLT

   
  Construction
  Ref. Specification : IS : 694 - 1990
Voltage Grade : Upto and including 1100 Volts.
Conductor : Aluminium: E.C grade aluminium as per Flexibility Class 1 and 2 of IS:8130-1984
Copper: Electrolytic grade bare annealed as per Flexibility Class 1 and 2 of IS:8130-1984
Insulation: Type A of IS : 5831 - 1984 for conductor temperature upto 70°C. Type C of IS : 5831- 1984 for conductor temperature upto 85°C.
Colour of Insulation:
1 Core Cable:
Red, Yellow, Blue, Black, Grey, Green, White or any colour as per customer requirement
2 Core Cables:
Red & Black
3 Core Cables: Red, Yellow & Blue
4 Core Cables:
Red, Yellow, Blue & Black
Shealth: Type ST 1 of IS: 5831- 1984 for conductor temprature up to
70oC. Type ST 2 of IS: 5831- 1984 for conductor temprature up to 85 oC
Colour of sheath:
Non-weather proof cables: Black or any other colour as per Purchaser's requirements.
Weather proof cables : The colour of sheat shall be Black only.
Tolerance of Thickness of Insulation :- The smallest of the measured values of thickness of insulation shall not fall below the nominal value specified in the relevant tables by more than (0.1mm +0.1 t1
)
Where t1
= Nominal thickness of insulation.
Tolerance of Thickness of Sheath:- The smallest of the measured values of thickness of sheath shall not fall below the nominal value specified in the relevant tables by more than (0.2mm +0.2
t5 )
Where
t5  = Nominal thickness of sheath
Laying-up of core for 2,3 and 4 core tables:- The cores are be laid togther with a suitable right hand lay.
Flat 2 and 3 core cables:- The cores are laid side side. In cae of 2 core flat cables with Earth continuity conductor the cores and the E.C.C are laid side by side in the same plane with E.C.C occupying the central position.
 
       
Current carrying capacity 2 cables, single phase
 
Nominal Area of Conductor
Number/ Nom. Dia Of wire
Thickness of Insulation
Approx Overall of Dia meter
In Conduit Trunking
Unenclosed Clipped directly to surface or on cable tray
Max. D.C.Resistance per km at 20oC
mm2
mm
mm
mm
Amps.
Amps.
Ohms
1.0
14/.3
0.7
2.8
11
12
18.10
1.5
22/.3
0.7
3.1
13
16
12.10
2.5
36/.3
0.8
3.8
18
22
7.41
4.0
56/.3
0.8
4.4
24
29
4.95
6.0
84/.3
0.8
5.3
31
37
3.30
10.0
80/.4 or 140/.3
1.0
6.8
42
51
1.91
16.0
126/.4
1.0
8.2
57
68
1.21
25.0
196/.4
1.2
10.0
71
86
0.780
35.0
276/.4
1.2
11.2
91
110
0.554
50.0
396/.4
1.4
13.5
120
145
0.386